161 research outputs found

    Real-Time Numerical Simulation for Accurate Soft Tissues Modeling during Haptic Interaction

    Get PDF
    The simulation of fabrics physics and its interaction with the human body has been largely studied in recent years to provide realistic-looking garments and wears specifically in the entertainment business. When the purpose of the simulation is to obtain scientific measures and detailed mechanical properties of the interaction, the underlying physical models should be enhanced to obtain better simulation accuracy increasing the modeling complexity and relaxing the simulation timing constraints to properly solve the set of equations under analysis. However, in the specific field of haptic interaction, the desiderata are to have both physical consistency and high frame rate to display stable and coherent stimuli as feedback to the user requiring a tradeoff between accuracy and real-time interaction. This work introduces a haptic system for the evaluation of the fabric hand of specific garments either existing or yet to be produced in a virtual reality simulation. The modeling is based on the co-rotational Finite Element approach that allows for large displacements but the small deformation of the elements. The proposed system can be beneficial for the fabrics industry both in the design phase or in the presentation phase, where a virtual fabric portfolio can be shown to customers around the world. Results exhibit the feasibility of high-frequency real-time simulation for haptic interaction with virtual garments employing realistic mechanical properties of the fabric materials

    RFID Gazebo-Based Simulator With RSSI and Phase Signals for UHF Tags Localization and Tracking

    Get PDF
    Radio Frequency Identification (RFID) technology is becoming very popular in the new era of Industry 4.0, especially for warehouse management, retails, and logistics. RFID systems can be used for objects identification, localization, and tracking, facilitating everyday operators' efforts. However, the deployment of RFID tags and reader antennas in real-world application scenarios is crucial and takes time. Indeed, deciding where to place tags and/or readers' requires examining many conditions. If some weaknesses appear in the design, the arrangement must be reconsidered. The proposed work presents a novel open-source RFID simulator that allows modeling environments and testing the deployment of RFID tags and antennas apriori. In such a way, validating the performance of the localization or tracking algorithms in simulation, possible weaknesses that could arise may be fixed before facilities are applied on the field. Any number of tags and antennas can be placed in any position in the created scenario, and the simulator provides the phase and the RSSI signals for each tag. Every reader antenna is parametrized so that different antennas of different vendors can be reproduced. The simulator is implemented as a plugin of Gazebo, a widely used robotic framework integrated with the Robot Operating System (ROS), to reach a broad audience. In order to validate the simulator, a warehouse scenario is modeled, and a tag localization algorithm that uses the phase unwrapping technique and hyperbolae intersection method employing a reader antenna mounted on a mobile robot is used to estimate the position of the tags deployed in the scenario. The outcomes of the experiments showed realistic results

    Virtual Stiffness: A Novel Biomechanical Approach to Estimate Limb Stiffness of a Multi-Muscle and Multi-Joint System

    Get PDF
    In recent years, different groups have developed algorithms to control the stiffness of a robotic device through the electromyographic activity collected from a human operator. However, the approaches proposed so far require an initial calibration, have a complex subject-specific muscle model, or consider the activity of only a few pairs of antagonist muscles. This study described and tested an approach based on a biomechanical model to estimate the limb stiffness of a multi-joint, multi-muscle system from muscle activations. The “virtual stiffness” method approximates the generated stiffness as the stiffness due to the component of the muscle-activation vector that does not generate any endpoint force. Such a component is calculated by projecting the vector of muscle activations, estimated from the electromyographic signals, onto the null space of the linear mapping of muscle activations onto the endpoint force. The proposed method was tested by using an upper-limb model made of two joints and six Hill-type muscles and data collected during an isometric force-generation task performed with the upper limb. The null-space projection of the muscle-activation vector approximated the major axis of the stiffness ellipse or ellipsoid. The model provides a good approximation of the voluntary stiffening performed by participants that could be directly implemented in wearable myoelectric controlled devices that estimate, in real-time, the endpoint forces, or endpoint movement, from the mapping between muscle activation and force, without any additional calibrations

    Smooth Coverage Path Planning for UAVs with Model Predictive Control Trajectory Tracking

    Get PDF
    Within the Industry 4.0 ecosystem, Inspection Robotics is one fundamental technology to speed up monitoring processes and obtain good accuracy and performance of the inspections while avoiding possible safety issues for human personnel. This manuscript investigates the robotics inspection of areas and surfaces employing Unmanned Aerial Vehicles (UAVs). The contribution starts by addressing the problem of coverage path planning and proposes a smoothing approach intended to reduce both flight time and memory consumption to store the target navigation path. Evaluation tests are conducted on a quadrotor equipped with a Model Predictive Control (MPC) policy and a Simultaneous Localization and Mapping (SLAM) algorithm to localize the UAV in the environment

    Exploiting Intrinsic Kinematic Null Space for Supernumerary Robotic Limbs Control

    Get PDF
    Supernumerary robotic limbs (SRLs) gained increasing interest in the last years for their applicability as healthcare and assistive technologies. These devices can either support or augment human sensorimotor capabilities, allowing users to complete tasks that are more complex than those feasible for their natural limbs. However, for a successful coordination between natural and artificial limbs, intuitiveness of interaction and perception of autonomy are key enabling features, especially for people suffering from motor disorders and impairments. The development of suitable human-robot interfaces is thus fundamental to foster the adoption of SRLs.With this work, we describe how to control an extra degree of freedom by taking advantage of what we defined the Intrinsic Kinematic Null Space, i.e. the redundancy of the human kinematic chain involved in the ongoing task. Obtained results demonstrated that the proposed control strategy is effective for performing complex tasks with a supernumerary robotic finger, and that practice improves users' control ability

    Evaluation of Spatiotemporal Patterns of the Spinal Muscle Coordination Output during Walking in the Exoskeleton

    Get PDF
    Recent advances in the performance and evaluation of walking in exoskeletons use various assessments based on kinematic/kinetic measurements. While such variables provide general characteristics of gait performance, only limited conclusions can be made about the neural control strategies. Moreover, some kinematic or kinetic parameters are a consequence of the control implemented on the exoskeleton. Therefore, standard indicators based on kinematic variables have limitations and need to be complemented by performance measures of muscle coordination and control strategy. Knowledge about what happens at the spinal cord output level might also be critical for rehabilitation since an abnormal spatiotemporal integration of activity in specific spinal segments may result in a risk for abnormalities in gait recovery. Here we present the PEPATO software, which is a benchmarking solution to assess changes in the spinal locomotor output during walking in the exoskeleton with respect to reference data on normal walking. In particular, functional and structural changes at the spinal cord level can be mapped into muscle synergies and spinal maps of motoneuron activity. A user-friendly software interface guides the user through several data processing steps leading to a set of performance indicators as output. We present an example of the usage of this software for evaluating walking in an unloading exoskeleton that allows a person to step in simulated reduced (the Moon's) gravity. By analyzing the EMG activity from lower limb muscles, the algorithms detected several performance indicators demonstrating differential adaptation (shifts in the center of activity, prolonged activation) of specific muscle activation modules and spinal motor pools and increased coactivation of lumbar and sacral segments. The software is integrated at EUROBENCH facilities to benchmark the performance of walking in the exoskeleton from the point of view of changes in the spinal locomotor output

    Adhesion State Estimation for Electrostatic Gripper Based on Online Capacitance Measure

    Get PDF
    Electroadhesion is a suitable technology for developing grippers for applications where fragile, compliant or variable shape objects need to be grabbed and where a retention action is typically preferred to a compression force. This article presents a self-sensing technique for electroadhesive devices (EAD) based on the capacitance measure. Specifically, we demonstrate that measuring the variation of the capacitance between electrodes of an EAD during the adhesion can provide useful information to automatically detect the successful grip of an object and the possible loss of adhesion during manipulation. To this aim, a dedicated electronic circuit is developed that is able to measure capacitance variations while the high voltage required for the adhesion is activated. A test bench characterization is presented to evaluate the self-sensing of capacitance during different states: (1) the EAD is far away from the object to be grasped; (2) the EAD is in contact with the object, but the voltage is not active (i.e., no adhesion); and (3) the EAD is activated and attached to the object. Correlation between the applied voltage, object material and shape and capacitance is made. The self-sensing EAD is then demonstrated in a closed-loop robotic application that employs a robot manipulator arm to pick and place objects of different kinds

    Insulin Glargine U100 Utilization in Patients with Type 2 Diabetes in an Italian Real-World Setting: A Retrospective Study

    Get PDF
    Background. This study is aimed at estimating the proportion of type 2 diabetes mellitus (T2DM) patients treated with basal insulin (insulin glargine U100) and at evaluating daily insulin dose, treatment pattern, and adherence to treatment of these patients. Methods. Data from administrative and laboratory databases of 3 Italian Local Health Units were retrospectively collected and analyzed. All patients with a diagnosis of T2DM between 01/01/2012 and 31/12/2012 were considered, and those with at least a prescription of insulin glargine between 01/01/2013 and 31/12/2014 were included and followed up for one year. For each patient, we evaluated HbA1c levels both at baseline and during the follow-up period and the daily average dose of insulin. Medication adherence was defined by using medication possession ratio (MPR) and reported as proportion of patients with MPR≥80%. Results. 7,422 T2DM patients were available for the study. According to the antidiabetic medication prescribed, patients were categorized into four groups: insulin glargine only, insulin glargine plus oral glucose-lowering drugs, insulin glargine plus rapid-acting insulin, and insulin glargine plus DPP-4 inhibitors. Median daily dose of insulin among insulin glargine only patients was higher than in other groups (35 IU vs. 20 IU, p<0.05), and a higher percentage of them achieved a target HbA1c value of less than 7.0% (53.8% vs. 30%, p<0.001). Adherence to insulin treatment was lowest (41%) in the insulin glargine only group compared to other groups (ranging from 58.4% to 64.4%), p<0.001. Conclusions. A large proportion of T2DM patients treated with insulin fail in achieving the glycemic target of HbA1c level<7%, irrespective of treatment regimen; however, basal insulin only is associated with lower therapeutic unsuccess. Adherence to antidiabetes medications is also suboptimal in these patients and should be addressed to improve long-term outcomes of reducing and preventing microvascular and macrovascular complications
    • …
    corecore